1. Althensensors
  2. Capteurs
  3. Capteurs de basculement & d’inclinaison
  4. Systèmes de mesure et de commutation de l'inclinaison
  5. NM1-IP-4L Tilt Measuring System

NM1-IP-4L Tilt Measuring System

Single axis tilt measuring system in aluminium enclosure (IP66)


Caractéristiques principales

  • Measuring range ±3° up to ±60° or 0 … 90°
  • Accuracy ±0,1° (up to ± 15°), 0,5% of measuring range (up to ±60°)
  • Analogue output 0 … (±)10 V or 0(4) … 20 mA (4-wire-technology)
  • Supply voltage 10 … 18 VDC or 18 … 30 VDC

About the NM1-IP-4L Tilt Measuring System

The single axis industrial tilt measuring system NM1-IP-4L is the combination of a non-contact inclination and sensor adapted electronics. The measuring system is designed for precise tilt measurement in one axis and intended for side assembly. Available tilt measuring ranges are ±3° to ±60° or 0 … 10° to 0 … 90°. The electrical wiring is realized in 4-wire-technology. For further evaluation of the measured inclination there are different standard analogue output signals available, depending on the ordered type.

The tilt measuring system is built into a robust EMC-safe die-cast aluminium enclosure (IP66), which is well suited for applications in rough and industrial environments.

Avez-vous besoin de ce capteur pour votre prochain projet?

Demandez un devis sans engagement ou envoyez-nous vos coordonnées pour une consultation gratuite et sans engagement. Nos ingénieurs commerciaux vous contacteront dans un délai maximum de 1 à 2 jours ouvrables.

Parler à un expert

Parlez à nos experts

Vous ne trouvez pas exactement ce que vous cherchez ? Nous proposons des capteurs et des systèmes de mesure standard, mais nous pouvons également vous aider à concevoir un capteur sur mesure ou une solution de mesure complète. N'hésitez pas à nous contacter pour obtenir des conseils ou un devis.

Parler à un expert

Spécifications techniques

Spécifications Valeur
Accuracy at 23 °c Up to ±15°: ±0,1°, Up to ±60°: 0,5% of measuring range, Up to ±65°: on request
Analogue output / burden 0 - 10 V / ±10 V, max. 1 mA (short-time short-circuit proof) 0 - 20 mA, 4 - 20 mA, max. 500 Ω
Cross-sensitivity < 1% up to ±60°
Dimensions (w x h x d) 175 x 80 x 57 mm (without EMC cable glands)
Electrical connection M16 x 1,5 EMC cable glands on internal spring-cage terminal blocks
Enclosure EMC-safe aluminium die-cast enclosure
Frequency range (-3 db) 2 Hz
Number of measuring axis 1
Power consumption ca. 3 W
Preferred measuring range ±3°, ±5°, ±10°, ±15, ± 20, ±30, ±45°, ±60° 0 - 10°, 0 - 30°, 0 - 45°, 0 - 60°, 0 - 90° other measuring ranges on request
Protection class P66
Supply voltage 10 - 18 VDC*, 18 - 30 VDC*, electronic is protected against voltage reversal
Temperature, operating -20 to +60 °C
Temperature, storage -20 to +60 °C
Voltage insulation between supply voltage and analogue output Galvanic isolation between supply voltage and analogue output, 200 V, higher voltage insulation on request
Weight 1.000 g

Produits apparentés

Besoin d'autre chose?

NM1-ISU-IP Tilt Measuring System

  • Measuring range adjustable up to 360°
  • With digital and analog connection
  • With RS232-Data Interface
Datasheet Voir le produit