1. Althensensors
  2. Capteurs
  3. Capteurs de basculement & d’inclinaison
  4. Systèmes de mesure et de commutation de l'inclinaison
  5. NM1-ISU-IP Tilt Measuring System

NM1-ISU-IP Tilt Measuring System

Single axis tilt measuring system with digital and analog connection


Caractéristiques principales

  • Single Axis Industrial Tilt Measuring System with RS232-Data Interface
  • Supply voltage 22 … 26 VDC
  • Adjustable measuring range up to 360°
  • Accuracy ±0.2°
  • RS232 Data Interface, optionally analogue output 4 … 20 mA)

About the NM1-ISU-IP Tilt Measuring System

The single axis industrial tilt measuring system NM1-ISU is designed for precise tilt measurement in X axis and intended for the side wall mounting. The inclination ranges are selectable via an internal DIP switch. The measuring data are output via a RS232 data interface. Optional an additional scalable analogue output 4… 20 mA is available.

The tilt measuring system is built-in into a robust EMC-safe aluminium die-cast enclosure (IP66), which is suited for applications in rough and industrial environments.

Avez-vous besoin de ce capteur pour votre prochain projet?

Demandez un devis sans engagement ou envoyez-nous vos coordonnées pour une consultation gratuite et sans engagement. Nos ingénieurs commerciaux vous contacteront dans un délai maximum de 1 à 2 jours ouvrables.

Parler à un expert

Parlez à nos experts

Vous ne trouvez pas exactement ce que vous cherchez ? Nous proposons des capteurs et des systèmes de mesure standard, mais nous pouvons également vous aider à concevoir un capteur sur mesure ou une solution de mesure complète. N'hésitez pas à nous contacter pour obtenir des conseils ou un devis.

Parler à un expert

Spécifications techniques

Spécifications Valeur
Accuracy ±0.2°
Adjustable measuring range Measuring range about internal DIP-Switch ±10°, ±20°, ±30°, ±45°, ±60°, ±90°, ±120°, ±180° Inclination
Data interface/analogue output/ power rating RS232 Data Interface, 4 - 20 mA (Option …-420..-), max. 500 Ohm
Dimensions (w x h x d) 150 x 65 x 36 mm (without EMC-cable gland)
Electrical connection: Standard: 3 m connecting cable (optionally are cable versions up to 10 m available) Type of cable: Unitronic FD CP plus 3 x 2 x 0.25 mm²
Enclosure EMC-safe aluminium die-cast enclosure
Hysteresis ±0.1°
Measuring frequency 0.4 Hz
Power consumption: ca. 3 W
Repeatability ±0.1°
Supply voltage: 22 - 26 VDC, electronics protected against voltage reversal
Temperature error ±0.015°/°C
Temperature, operating -20 to +60 °C
Temperature, storage -20 to +60 °C
Weight Approx. 630 g with 3 m connecting cable, electronics not moulded in casting compound Approx. 1150 g with 10 m connecting cable, electronics not moulded in casting compound

Produits apparentés

Besoin d'autre chose?

NM2-IP2-2L Tilt Measuring System

  • Measuring range ±3° up to ±45° per axis
  • In a compact EMC-safe aluminium enclosure
  • Accuracy ±0.1° to ±0.25°
Datasheet Voir le produit