X005 Galvanic Isolation Amplifier
For use with intrinsically safe sensors
Caractéristiques principales
- ATEX and IECEx approval
- EX I (M1), EX (1)GD certified
- Super fast 4.7kHz (-3dB) bandwith
- Wide power supply range
- Voltage and current output options
- Three or five wire mode connection
About the X005 Galvanic Isolation Amplifier
The X005 has been designed specifically for use with Intrinsically Safe position sensors and is certified intrinsically safe I and IIC.
The Intrinsically Safe sensors are ratiometric i.e. the output signal scales with the supply voltage. To ensure the safe area signal accurately corresponds with sensor displacement it is important that the sensor supply is correct.
The X005 Galvanic Isolation Amplifier provides a regulated and resistively limited +5V dc power supply required by the Intrinsically Safe sensors. It can be connected in three or five wire modes. Used in five wire mode positive and negative sense inputs enable the X005 to dynamically adjust the sensor supply thus ensuring the correct voltage across the sensor. Connected in this way the X005 can compensate for 15Ω conductor resistance.
The sense terminals are linked internally so the end user can use the X005 in three wire or five wire mode without the need to fit or remove external links.
The X005 has an input power supply range of 12 to 30 volts dc, making it suitable for a wide range of hazardous area applications. It is tri-port isolated providing isolation between the amplifier power supply, the hazardous area and the X005 output signal. The sensor supply and output are transformer coupled providing 2.5kV isolation between the safe and hazardous area circuits eliminating the requirement for a high-integrity earth.
The output is configured to either 0.5 to 9.5V or -20mA and has a bandwidth of 4.7kHz, making it ideal for servo control loops.
Avez-vous besoin de ce capteur pour votre prochain projet?
Demandez un devis sans engagement ou envoyez-nous vos coordonnées pour une consultation gratuite et sans engagement. Nos ingénieurs commerciaux vous contacteront dans un délai maximum de 1 à 2 jours ouvrables.
Téléchargements de produits
Parlez à nos experts
Vous ne trouvez pas exactement ce que vous cherchez ? Nous proposons des capteurs et des systèmes de mesure standard, mais nous pouvons également vous aider à concevoir un capteur sur mesure ou une solution de mesure complète. N'hésitez pas à nous contacter pour obtenir des conseils ou un devis.
Parler à un expertSpécifications techniques
Spécifications | Valeur |
---|---|
-40°C to +100°C storage | |
Approximately 70mA (current O/P) | |
Ex II (1) GD | |
Ambient temperature range | -20°C to +60°C working |
Atex approval | Ex I (M1) |
Bandwidth | DC to 4.7kHz (-3db) |
Current consumption (24v supply) | Approximately 50mA (voltage O/P) |
Current loop | 4-20mA, load resistance 0-1KΩ |
Electromagnetic compatibility | EN561236-2-1:2006 (EN31326-1:2006) |
Housing | 97.3 x 22.5 x 111.9mm |
Isolation | 2500V between safe area terminals and hazardous area terminals, 50V between power rail (J4) and optput (J3) |
Lead resistance for 15ma | 15Ω max (all connections) |
Mounting | 35 x 7.5mm top-hat rail (DIN 46277-3) |
Non-linearity | <+/- 0.1% FS |
Protection class | IP20 |
Rise time | <200μs for 10-90% step change |
Sensor input resistance | >5MΩ |
Sensor supply | 5V at 15mA max |
Setting time to 1% of span | <300μs for 10-90% step change |
Temperature drift | <0.01% FS/°C for voltage outputs |
Voltage | 0.5-9.5V - output resistance 5Ω |
Voltage | 24V DC nom 12V-30V |
Produits apparentés
Besoin d'autre chose?
X500 Rotary Inductive Position Sensor
- Calibrated between 16° to 160°
- Intrinsically safe for gas to: Ex II 1G
- Compact, durable and reliable
X502 Rotary Inductive Position Sensor
- Calibrated between 5° to 15°
- With smaller angles of deflection
- Full EMC protection built in
X505 Rotary Inductive Position Sensor
- Calibrated between 15° to 160°
- Rugged stainless steel body, flange & shaft
- Angle set to customer’s requirement