1. Althen Sensors
  2. Instrumentation
  3. Amplificateurs de Mesure & Afficheurs
  4. Amplificateurs à jauge de contrainte
  5. SG-AP Strain Gauge Amplifiers

SG-AP Strain Gauge Amplifiers

Single Channel Strain Gauge Amplifier with Aluminium Enclosure


About the SG-AP Strain Gauge Amplifiers

The single channel strain gauge measuring amplifier SG-AP allows the supply and signal evaluation of a transducer with a strain gauge full bridge greater than 300 ohms. Input and output are galvanically isolated. The connection is done in 4-wire technology via a pluggable screw clamp terminal block. For further evaluation standard analogue outputs are available. The measuring amplifier is available in 3 versions with different sensitivity. By means of potentiometer for zero and amplification, a calibration correction can be carried out.

 

Key features SG-AP

  • Supply voltage 10 - 18 VDC / 18 - 30 VDC
  • Analogue output 0 - 10 V / ±10 V
  • Aluminium profile enclosure (IP20)
  • Dimensions (W x H x D) 104 x 55 x 30 mm

Avez-vous besoin de ce capteur pour votre prochain projet?

Demandez un devis sans engagement ou envoyez-nous vos coordonnées pour une consultation gratuite et sans engagement. Nos ingénieurs commerciaux vous contacteront dans un délai maximum de 1 à 2 jours ouvrables.

Parler à un expert

Parlez à nos experts

Vous ne trouvez pas exactement ce que vous cherchez ? Nous proposons des capteurs et des systèmes de mesure standard, mais nous pouvons également vous aider à concevoir un capteur sur mesure ou une solution de mesure complète. N'hésitez pas à nous contacter pour obtenir des conseils ou un devis.

Parler à un expert

Spécifications techniques

Spécifications Valeur
Analogue output 0 - 10 V, ±10 V, max. 1 mA (short-period short-circuit proof)
Dimension (b x h x d) 104 x 55 x 30 mm
Electrical connection Pluggable screw clamp terminal block
Enclosure Aluminium profile enclosure
Input resistance >3 MΩ
Isolating proof voltage input to output 200 V, higher isolated proof voltage on request
Limit frequency (-3 db) Version -GF10Hz: 10 Hz Version, -GF1kHz: 1 kHz
Max. input sensitivity Version -1: 1 mV/V (Range Potentiometer G: 0.5 - 1.5 mV/V) | Version -2: 2 mV/V (Range Potentiometer G: 1.5 - 2.5 mV/V) | Version -3: 3 mV/V (Range Potentiometer G: 2.5 - 3.5 mV/V)
Non-linearity ±0.05 % FSO
Number of measuring channels 1 (full bridge resistance >300 Ω)
Power consumption 2 W
Strain gauge excitation supply 2.5 VDC, 5 VDC, 10 VDC (±2 %, max. 35 mA)
Supply voltage 10 - 18 VDC, 18 - 30 VDC, electronics protected against reversal voltage
Temperature, operating +10 - +50 °C
Temperature, storage -20 - +60 °C
Weight 140 g