GRAPHTEC GL860 Isolated Multi-CH data Logger
High voltage withstanding multichannel data logger with 20 to 200 measuring channels and increased accuracy
Key features
- 4 types of input terminals lineup including 30CH
- Expandable from 20ch to max. 200ch, enabling measurement of various phenomena
- Compatible with remote control service G-REMOTE
- 6 new features:Faster sampling interval, Memory loop functions, CH copy function, Alarm history, Inter-CH operation, Modbus communication
- Wireless measurement from your PC is available with the optional wireless LAN unit
About the GL860 Isolated Multi-CH data Logger
Data logger with 20 or 30 analog measuring channels for voltage (from 20 mV to 100 V), temperature (thermocouples, PT100, PT1000), humidity (e.g. B-530) and the option with higher measuring accuracy and maximum dielectric strength of the input channels CAT II 300V
New functions
- Faster sampling rate
- Memory loop function
- Copy function for channels
- Alarm history
- Calculation function between two channels
- Modbus communication
Analog multifunction inputs
The GL860 has an isolated input system which ensures that signals are not influenced by signal inputs on other channels. The multifunction inputs enable combined measurements of various measured variables such as voltage, temperature, humidity, logic and pulses.
Terminal blocks with multifunctional inputs
- B-563: Input terminal block, 20 channels
- B-563SL: Screwless input terminal block, 20 channels
- B-563SL-30: Screwless input terminal block, 30 channels
- B-565: Input terminal block with increased dielectric strength CAT II 300V, 20 channels
4 channels for logic/pulse input
There are 4 channels available for logic and pulse input signals. In pulse mode, the following values can be measured for speed and flow rate: Counter, pulse/sample rate and revolutions per minute. Measuring range from 20 mV to 100 V.
- Temperature: Thermocouples: K, J, E, T, R, S, B, N, C, W
- Resistance thermometers: Pt100, JPt100, Pt1000 (only with B-565)
- Humidity: 0 ... 100 % rH (only with sensor B-530)
- Pulse: 4 channels (counter, pulse/scanning interval and revolutions per minute)
- Logic: 4 channels
- Channel extension to 200 channels
The standard version has 20 or 30 analog input channels. The number of input channels can be increased to a maximum of 200 channels by connecting optional expansion modules (B-566) and input terminal blocks (B-563, B-563SL, B-563SL-30 or B-565).
Features
- Measuring ranges: voltage, temperature, humidity
- Measuring channels: up to 200
- Resolution: 16 bit
- Sampling interval: 5ms to 1h per channel (depending on the number of channels)
- Interface: Ethernet, USB, W-LAN
- Operation: stand-alone, PC-based, FTP, http
Scope of delivery
- 18 months warranty (from date of invoice)
- Calibration certificate
- Power supply unit
- Menu guide
- Quick guide
- USB cable
- Display protection film
- Screwdriver
W-LAN option
The WLAN option enables wireless communication with other devices. If the GL860 is configured as a station, PCs and mobile devices can communicate directly with the data logger via WLAN.
Combination of GL100-WL and GL860
The GL100-WL data logger can be connected to the GL860 series data loggers via WLAN. The various measuring sensors of the GL100-WL extend the range of possible measurements. The measured value then appears in a file together with the measured values of the GL860. The GL860 retrieves the information directly from the GL100-WL.
Communication with PC or mobile devices
The GL860 data logger can be connected to a LAN network (Local Area Network) via a WLAN access point. The measurement data can be evaluated via the PC or mobile devices using the application software. The device can also be configured via the network.
Models (see kits):
GL860-EU-563 with 20 analogue measuring channels for voltage (from 20mV to 100 V), temperature (thermocouples) and humidity (e.g. B-530).
GL860-EU-563SL with 20 analogue measuring channels, with screwless clamp fastening for voltage (from 20mV to 100 V), temperature (thermocouples) and humidity (e.g. B-530).
GL860-EU-563SL-30 with 30 analogue measuring channels, with screwless terminal mounting for voltage (from 20mV to 100 V), temperature (thermocouples) and humidity (e.g. B-530).
GL860-EU-565 with 20 analogue measuring channels, with screwless clamp fastening for voltage (from 20mV to 100 V), temperature (thermocouples, PT100, PT1000) and humidity (e.g. B-530). Higher measuring accuracy and dielectric strength in the CAT II 300V input channels.
Do you need this sensor for your next project?
Request a no-obligation quote or send us your contact details for a free, no-obligation consultation. Our sales engineers will then contact you within a maximum of 1 to 2 working days.
Product downloads
Talk to our experts
Not exactly what you are looking for? We offer standard sensors, but can also help you with sensors adapted for you or a fully customised measurement solution. Contact us for advice or pricing.
Talk to an expert