FDRF089 Geometry Measurement System
Designed to control the geometrical parameters (width and thickness) and the temperature of the tapes
About the FDRF089 Geometry Measurement System
The system is designed to control the geometrical parameters (width and thickness) and the temperature of the tapes, in particular, packing straps during the manufacturing process.
The system is applied in the mass production. Production line is the place of installation.
Technical characteristics of the system can be changed for a specific task.
Features FDRF089
- Width measurement accuracy: ±10 µm
- Thickness measurement accuracy: ±5 µm
Do you need this sensor for your next project?
Request a no-obligation quote or send us your contact details for a free, no-obligation consultation. Our sales engineers will then contact you within a maximum of 1 to 2 working days.
Talk to our experts
Not exactly what you are looking for? We offer standard sensors, but can also help you with sensors adapted for you or a fully customised measurement solution. Contact us for advice or pricing.
Talk to an expertTechnical Specifications
Specification | Value |
---|---|
Accuracy of the thickness measurement | ±5 µm |
Accuracy of the width measurement | ±10 µm |
Max measurement speed | 2000 measurement/s |
Measurement range for the tape thickness | 0.02mm to 20mm |
Measurement range for the tape width | ±0.2 - 20mm |
Model of micrometer | RF651-25 |
Model of pda | RF307 |
Model of temperature sensor | OMEGA OS-136-1-MA |
Number of tapes controlled simultaneously | 6 |
Number of temperature control points | 3 |
Operating temperature | 1°C to 35°C |
Power consumption | 4W |
Power supply | Three-phase AC network with frequency (± 1) Hz, rated voltage 220/380V with a tolerance of ± 10% voltage |