These probes were designed and patented for applications requiring a very high range of incidence angles. As their name suggests, they are capable of near-omni-directional flow measurement. Omniprobes are also ideal in applications where the predominant direction of the flow is not known in advance or where the probe may see a complete reversal of the flow during testing. A micro-machined spherical tip accommodates 12 pressure ports that allow for measurement of +/- 150 degrees of flow angle.

 

Key features Omniprobes

  • 12 hole
  • Spherical tip geometry
  • Standard tip diameter 6.35 and 9.53 mm
  • Capable of measuring flow vectors up to ±150 °
  • Temperature ratings up to 500° C
  • High accuracy NIST traceable aerodynamic calibrations
  • Up to 9000 discrete aerodynamic calibration points per speed
  • 303, 304 Stainless steel construction; Optional nickel based super alloy for high strength
  • Custom engineering solutions available
  • Available in Straight and L-shaped geometries
  • Standard media: non-reactive gases, air, water, and other fluids
  • Angle error less than ±2°
  • Velocity error less than ±3% or ±0.005 m/s (whichever is larger)

 

Applications Omniprobes

  • High-angularity wake measurements around automobile wheels
  • Wake measurements behind automobiles and rolling-road wind tunnels
  • Wind engineering or combustor swirl flows

Do you need this sensor for your next project?

Request a no-obligation quote or send us your contact details for a free, no-obligation consultation. Our sales engineers will then contact you within a maximum of 1 to 2 working days.

Talk to an expert

Talk to our experts

Not exactly what you are looking for? We offer standard sensors, but can also help you with sensors adapted for you or a fully customised measurement solution. Contact us for advice or pricing.

Talk to an expert

Technical Specifications

Specification Value
Average measured angular deviation <1°
Average measured velocity deviation ± 3% or ±1 m/s (whichever is larger)
Probe calibrations 5 m/s to Mach 1.0
Temperature ratings to 900°C
Tip diameters 6.35 mm