X005 Galvanische Isolatieversterker (ATEX/IECEx)
Voor gebruik met intrinsiek veilige sensoren
Belangrijkste kenmerken
- ATEX and IECEx approval
- EX I (M1), EX (1)GD certified
- Super fast 4.7kHz (-3dB) bandwith
- Wide power supply range
- Voltage and current output options
- Three or five wire mode connection
About the X005 Galvanic Isolation Amplifier
The X005 has been designed specifically for use with Intrinsically Safe position sensors and is certified intrinsically safe I and IIC.
The Intrinsically Safe sensors are ratiometric i.e. the output signal scales with the supply voltage. To ensure the safe area signal accurately corresponds with sensor displacement it is important that the sensor supply is correct.
The X005 Galvanic Isolation Amplifier provides a regulated and resistively limited +5V dc power supply required by the Intrinsically Safe sensors. It can be connected in three or five wire modes. Used in five wire mode positive and negative sense inputs enable the X005 to dynamically adjust the sensor supply thus ensuring the correct voltage across the sensor. Connected in this way the X005 can compensate for 15Ω conductor resistance.
The sense terminals are linked internally so the end user can use the X005 in three wire or five wire mode without the need to fit or remove external links.
The X005 has an input power supply range of 12 to 30 volts dc, making it suitable for a wide range of hazardous area applications. It is tri-port isolated providing isolation between the amplifier power supply, the hazardous area and the X005 output signal. The sensor supply and output are transformer coupled providing 2.5kV isolation between the safe and hazardous area circuits eliminating the requirement for a high-integrity earth.
The output is configured to either 0.5 to 9.5V or -20mA and has a bandwidth of 4.7kHz, making it ideal for servo control loops.
Heeft u deze sensor nodig voor uw project?
Vraag een vrijblijvende offerte aan of stuur ons uw contactgegevens voor een gratis en vrijblijvend gesprek. Onze sales engineers nemen dan binnen maximaal 1 tot 2 werkdagen contact met u op.
Product downloaden
Praat met onze experts
Niet precies wat u zoekt? Wij bieden standaard sensoren, maar kunnen u ook helpen met voor u aangepaste sensoren of een volledig op maat gemaakte meetoplossing. Neem contact met ons op voor advies of prijzen.
Praat met een expertTechnische specificaties
Specificaties | Waarde |
---|---|
-40°C to +100°C storage | |
Approximately 70mA (current O/P) | |
Ex II (1) GD | |
Ambient temperature range | -20°C to +60°C working |
Atex approval | Ex I (M1) |
Bandwidth | DC to 4.7kHz (-3db) |
Current consumption (24v supply) | Approximately 50mA (voltage O/P) |
Current loop | 4-20mA, load resistance 0-1KΩ |
Electromagnetic compatibility | EN561236-2-1:2006 (EN31326-1:2006) |
Housing | 97.3 x 22.5 x 111.9mm |
Isolation | 2500V between safe area terminals and hazardous area terminals, 50V between power rail (J4) and optput (J3) |
Lead resistance for 15ma | 15Ω max (all connections) |
Mounting | 35 x 7.5mm top-hat rail (DIN 46277-3) |
Non-linearity | <+/- 0.1% FS |
Protection class | IP20 |
Rise time | <200μs for 10-90% step change |
Sensor input resistance | >5MΩ |
Sensor supply | 5V at 15mA max |
Setting time to 1% of span | <300μs for 10-90% step change |
Temperature drift | <0.01% FS/°C for voltage outputs |
Voltage | 0.5-9.5V - output resistance 5Ω |
Voltage | 24V DC nom 12V-30V |
Gerelateerde producten
Heeft u iets anders nodig?
X500 Inductieve Rotatiesensor (ATEX/IECEx)
- Gekalibreerd tussen 16° tot 160°
- Intrinsiek veilig voor gas naar: Ex II 1G
- Compact, duurzaam en betrouwbaar
X502 Inductieve Rotatiesensor (ATEX/IECEx)
- Gekalibreerd tussen 5° en 15°
- Met kleinere afbuigingshoeken
- Volledige ingebouwde EMC-bescherming
X505 Inductieve Rotatiesensor (ATEX/IECEx)
- Gekalibreerd tussen 15° tot 160°
- Robuuste roestvrijstalen behuizing, flens en as
- Hoek ingesteld op klantwens