1. Althensensors
  2. Sensors
  3. Weighing sensors and load cells
  4. Bending shear beam load cells
  5. FTKL Shear Beam Load Cell

FTKL Shear Beam Load Cell

Accuracy class C4/C5 (OIML R60)


Key features

  • Measuring ranges: 500, 1000, 1500, 2000, 3000, 5000kg
  • For tensile and compressive loads
  • Special steel construction
  • Combined error: < +/- 0.02% (0.017% C4; 0.014% C5)
  • Output signal normalized: 3 mV/V ±0.1%

General information


The FTKL shear beam transducer is suitable for force and weight measurements in tension and compression. Due to its internal design it is relatively insensitive to lateral loads. The transducer is made of high-strength tool steel and is splash-proof (tight IP67).

For installation, it is essential to use fasteners such as screws, bolts, etc. made of high-strength steel. For screws, the thread length used must be at least equal to the thread diameter. In addition, the mechanical load limit of the material must be taken into account when designing the weighing equipment, taking safety reserves into account.

Properties

  • Measuring ranges: 500, 1000, 1500, 2000, 3000, 5000kg
  • For tensile/compressive load
  • Special steel construction
  • Combined error: < +/- 0.02% (0.017% C4; 0.014% C5)
  • Output signal normalized: 3 mV/V ±0.1%
  • Supply voltage: 18V
  • Protection class: IP67

Do you need this sensor for your next project?

Request a no-obligation quote or send us your contact details for a free, no-obligation consultation. Our sales engineers will then contact you within a maximum of 1 to 2 working days.

Talk to an expert

Talk to our experts

Not exactly what you are looking for? We offer standard sensors, but can also help you with sensors adapted for you or a fully customised measurement solution. Contact us for advice or pricing.

Talk to an expert

Technical Specifications

Specification Value
Combined error ≤±0.02% | ≤±0.017% | ≤±0.014%
Compensated temperature range -10 °C / +40 °C
Creep at nominal load in 30 minutes 0.02%
Deflection at nominal load 0.4 mm
Input resistance 350 Ω ±3.5
Insulation resistance ≥5000 MΩ
Material Special steel
Max supply voltage without damage 18 V
Minimum verification interval (v min) E max / 10000 | E max / 15000 | E max / 20000 | E max / 18000
Nominal load (e max) 500 - 1000 - 1500 kg, 2000 - 3000 - 5000 kg | 500 - 1000 kg, 1500 - 2000 kg | 3000 - 5000 kg
Oiml r60 accuracy class • verification intervals C3 • 3000 | C4 • 4000 | C5 • 5000
Operating temperature range -35 °C / +65 °C
Output resistance 350 Ω ±3.5
Protection class IP67
Rated output 3 mV/V ±0.1%
Safe overload (% of full scale) 150%
Temperature effect on span 0.0014% °C
Temperature effect on zero 0.0018% °C
Ultimate overload (% of full scale) 300%
Zero balance ≤±1%

Related products

Need something else?

T12 Weight Module for Loadcells

  • Range: 30 to 2000kg
  • Upper plate with a compression joint in AISI 304 stainless steel and rubber.
  • Lower plate and block in galvanized steel
Datasheet View product