X005 Galvanic Isolation Amplifier
For use with intrinsically safe sensors
Nyckelfunktioner
- ATEX and IECEx approval
- EX I (M1), EX (1)GD certified
- Super fast 4.7kHz (-3dB) bandwith
- Wide power supply range
- Voltage and current output options
- Three or five wire mode connection
About the X005 Galvanic Isolation Amplifier
The X005 has been designed specifically for use with Intrinsically Safe position sensors and is certified intrinsically safe I and IIC.
The Intrinsically Safe sensors are ratiometric i.e. the output signal scales with the supply voltage. To ensure the safe area signal accurately corresponds with sensor displacement it is important that the sensor supply is correct.
The X005 Galvanic Isolation Amplifier provides a regulated and resistively limited +5V dc power supply required by the Intrinsically Safe sensors. It can be connected in three or five wire modes. Used in five wire mode positive and negative sense inputs enable the X005 to dynamically adjust the sensor supply thus ensuring the correct voltage across the sensor. Connected in this way the X005 can compensate for 15Ω conductor resistance.
The sense terminals are linked internally so the end user can use the X005 in three wire or five wire mode without the need to fit or remove external links.
The X005 has an input power supply range of 12 to 30 volts dc, making it suitable for a wide range of hazardous area applications. It is tri-port isolated providing isolation between the amplifier power supply, the hazardous area and the X005 output signal. The sensor supply and output are transformer coupled providing 2.5kV isolation between the safe and hazardous area circuits eliminating the requirement for a high-integrity earth.
The output is configured to either 0.5 to 9.5V or -20mA and has a bandwidth of 4.7kHz, making it ideal for servo control loops.
Behöver du den här sensorn till ditt nästa projekt?
Begär en offert eller lämna dina uppgifter för att få mer information från en av våra experter.
Produktnedladdningar
Få det på ditt sätt
Inte exakt vad du letar efter? Vi erbjuder standardsensorer, men kan också hjälpa dig med en komplett skräddarsydd lösning. Kontakta oss för rådgivning eller budgetprissättning.
Prata med en expertRelaterade produkter
Behöver du något annat?
X500 Rotary Inductive Position Sensor
- Calibrated between 16° to 160°
- Intrinsically safe for gas to: Ex II 1G
- Compact, durable and reliable
X502 Rotary Inductive Position Sensor
- Calibrated between 5° to 15°
- With smaller angles of deflection
- Full EMC protection built in
X505 Rotary Inductive Position Sensor
- Calibrated between 15° to 160°
- Rugged stainless steel body, flange & shaft