1. Althensensors
  2. Sensorer
  3. Vägningssensorer och lastceller
  4. Knapptyp lastceller
  5. ALL Single Point Load Cell

ALL Single Point Load Cell

For platforms 250 x 350mm

Se tekniska specifikationer

Nyckelfunktioner

  • Capacity: 3, 5, 10, 15, 20, 30, 50kg
  • Combined error ≤ ±0.02% (0.017% C4; 0.014% C5)
  • Aluminium alloy
  • Protection class IP65

General information


The ALL platform load cell is suitable for series use in weighing and batching systems, level measurement equipment and general force measurement systems where accurate measurements are required at low cost.


Features

  • Measuring range: 3, 5, 10, 15, 20, 30, 50kg
  • Aluminum alloy
  • Combined error: ≤±0.02% (0.017% C4; 0.014% C5).
  • Protection class: IP65
  • Approved according to OIML R60 C3, optional C4 and C5.

Options

  • ATEX approval Ex II 1GD (zone 0-1-2-20-21-22)
  • OIML R60 C4
  • OIML R60 C5
  • Stainless steel bracket

Safety notice:
When used as a tensile force transducer, it is essential to install additional safety measures such as catch straps, catch chains, etc., so that the load is absorbed in the event of a breakage of the transducer, which can never be completely ruled out.

Behöver du den här sensorn till ditt nästa projekt?

Begär en offert eller lämna dina uppgifter för att få mer information från en av våra experter.

Prata med en expert

Produktnedladdningar

Få det på ditt sätt

Inte exakt vad du letar efter? Vi erbjuder standardsensorer, men kan också hjälpa dig med en komplett skräddarsydd lösning. Kontakta oss för rådgivning eller budgetprissättning.

Prata med en expert

Tekniska specifikationer

Specifikation Värde
Compensated temperature range -10 °C / +40 °C
Creep at nominal load in 30 minutes 0.015%
Deflection at nominal load 0.5 mm
Input resistance 409 Ω ±6
Insulation resistance ≥5000 MΩ
Max supply voltage without damage 18 V
Measurement range 3, 5, 10, 15, 20, 30, 50kg
Operating temperature range -35 °C / +65 °C
Output resistance 350 Ω ±3
Rated output 2 mV/V ±10%
Safe overload (% of full scale) 150%
Temperature effect on span 0.0014% °C
Temperature effect on zero 0.0017% °C
Ultimate overload (% of full scale) 300%
Zero balance ≤ ±2%